Inductively Coupled Plasma Mass Spectrometry ( ICP-MS ) Instruments

NexION 1000 ICP Mass Spectrometer

Ideal for high-throughput testing laboratories running routine multi-element analysis, the NexION 1000 ICP-MS features:

  • A dedicated SMARTintro™ sample introduction module with integrated All Matrix Solution delivers long-term stability while handling high dissolved solids
  • Three quadrupoles and the unique capability of the Universal Cell to switch between Collision and Reaction modes using a single gas combine to offer efficient interference removal, requiring minimal switching times (<15 sec) and increasing your productivity
  • Extended Dynamic Range capabilities offer the ability to detect high- and low-level elements in a single sample run
  • The industry’s fastest data acquisition speed (100,000 points/sec) to handle any particle size
  • A new solid-state RF generator with revolutionary LumiCoil™ technology – first ICP-MS RF coil that requires no maintenance or cooling
  • Triple Cone Interface with Quadrupole Ion Deflector, delivering no maintenance beyond the cones
  • Syngistix™ software provides an intuitive interface that mirrors your workflow, with left-to-right, icon-based navigation that guides you through your analysis. Plus, it’s a cross-platform solution, easing the transition from technique to technique

The NexION 1000 ICP-MS – No interference between you and better throughput.

 

 

NexION 2000C ICP Mass Spectrometer

 

Ideal for labs doing QA/QC or running challenging matrices, the NexION 2000C ICP-MS features:

  • A dedicated SMARTintro™ High Matrix sample-introduction module with integrated All Matrix Solution allows the ability to handle high dissolved solids
  • Extended Dynamic Range capabilities provide the ability to detect high-and low-level elements in a single sample run
  • Three quadrupoles, three gas channels, and three modes of operation combine to offer better interference removal, delivering better detection limits/improved data accuracy
  • The industry’s fastest data acquisition speed on the market (100,000 points/sec) to handle any particle size
  • A new solid-state RF generator with revolutionary LumiCoil™ technology – first ICP-MS RF coil that requires no maintenance or cooling
  • Triple Cone Interface with Quadrupole Ion Deflector, delivering no maintenance beyond the cones
  • Syngistix™ software provides an intuitive interface that mirrors your workflow, with left-to-right, icon-based navigation that guides you through your analysis. Plus, it’s a cross-platform solution, easing the transition from technique to technique

The NexION 2000 ICP-MS – Triple Quad Power Meets Single Quad Versatility.

 

 

NexION 5000 Multi-Quadrupole ICP Mass Spectrometer

 

The multi-award-winning NexION 5000 ICP-MS is equipped with a host of new and proprietary technologies which together surpass traditional triple-quad capabilities and redefine your expectations:

  • Four quadrupoles:
    • First: Quadrupole Ion Deflector (Q0) directs ions to the entrance of the first mass filter
    • Second: Transmission Analyzer Quadrupole 1 (Q1, full-sized for <0.7 amu mass resolution), acts as a mass filter or as an ion guide to direct ions to the Quadrupole Universal Cell
    • Third: Quadrupole Universal Cell (Q2), empowered by dynamic bandpass tuning, prevents side reactions with residual gases in the cell
    • Fourth: Transmission Analyzer Quadrupole 2 (Q3, full-sized for <0.7 amu mass resolution), acts as a mass filter or as an ion guide to direct ions to the detector
  • Extended Dynamic Range (EDR) increases linear dynamic range to 1012, allowing to run both high and low concentration analytes in a single analytical run, resulting in fewer re-runs
  • Low maintenance for greater uptime:
    • Triple Cone Interface with patent-pending OmniRing™ combined with Quadrupole Ion Deflector deliver no maintenance beyond cones​, for continual operation and improved stability
    • 34 MHz free-running RF generator offers trouble-free user experience – the plasma is generated by the unique LumiCoil™ RF load coil, which is air cooled (does not require water or gas cooling), so maintenance-free, eliminating need to replace plasma load coils
  • External status lighting provides easy visibility of state of analysis, optimizing efficiencies
  • Syngistix™ for ICP-MS software (v. 3.0 or higher) brings together the power of the triple-quad ion optics with an user-friendly workflow in a contemporary user interface
  • Certified to be able to be upgraded to meet SEMI S2/S8 (emergency button) delivers ease of integration in clean room facilities

 

 